ConcreteDurability#
Attribute Name |
Data Type |
Description |
|---|---|---|
no |
int |
Object number |
user_defined_name_enabled |
bool |
User-defined name enabled |
name |
str |
Name |
members |
List[int] |
Assigned to Members No. |
member_sets |
List[int] |
Assigned to Member Sets No. |
surfaces |
List[int] |
Assigned to Surfaces No. |
deep_beams |
List[int] |
Assigned to Deep Beams No. |
shear_walls |
List[int] |
Assigned to Shear Walls No. |
no_risk_of_corrosion_or_attack_enabled |
bool |
No risk of corrosion or attack enabled |
no_risk_of_corrosion_or_attack |
No risk of corrosion or attack |
|
corrosion_induced_by_carbonation_enabled |
bool |
Corrosion induced by carbonation enabled |
corrosion_induced_by_carbonation |
Corrosion induced by carbonation |
|
corrosion_induced_by_chlorides_enabled |
bool |
Corrosion induced by chlorides enabled |
corrosion_induced_by_chlorides |
Corrosion induced by chlorides |
|
corrosion_induced_by_chlorides_from_sea_water_enabled |
bool |
Corrosion induced by chlorides from sea water enabled |
corrosion_induced_by_chlorides_from_sea_water |
Corrosion induced by chlorides from sea water |
|
freeze_thaw_attack_enabled |
bool |
Freeze / thaw attack enabled |
freeze_thaw_attack |
Freeze / thaw attack |
|
chemical_attack_enabled |
bool |
Chemical attack enabled |
chemical_attack |
Chemical attack |
|
concrete_corrosion_induced_by_wear_enabled |
bool |
Concrete corrosion induced by wear enabled |
concrete_corrosion_induced_by_wear |
Concrete corrosion induced by wear |
|
structural_class_type |
Structural class type |
|
userdefined_structural_class |
User-defined structural class |
|
design_working_life |
Design working life |
|
increase_design_working_life_from_50_to_100_years_enabled |
bool |
Increase design working life from 50 to 100 years enabled |
position_of_reinforcement_not_affected_by_construction_process_enabled |
bool |
Position of reinforcement not affected by construction process enabled |
special_quality_control_of_production_enabled |
bool |
Special quality control of production enabled |
nature_of_binder_without_fly_ash_enabled |
bool |
Nature of the binder based on CEN without fly ash enabled |
air_entrainment_of_more_than_4_percent_enabled |
bool |
Air entrainment of more than 4% enabled |
compact_coating_enabled |
bool |
Compact coating enabled |
adequate_cement_enabled |
bool |
Adequate cement enabled |
maximum_equivalent_water_to_cement_ratio |
Maximum equivalent water-to-cement ratio | vct_ekv |
|
strength_class_of_the_concrete_enabled |
bool |
The strength class of the concrete is at least two classes above the indicative strength class |
increase_of_minimum_concrete_cover_type |
Increase of minimum concrete cover type |
|
increase_of_minimum_concrete_cover_factor |
float |
Increase of minimum concrete cover factor | Δc_dur,γ |
stainless_steel_enabled |
bool |
Stainless steel enabled |
stainless_steel_type |
Stainless steel type |
|
stainless_steel_factor |
float |
Stainless steel factor | Δc_dur,st |
additional_protection_enabled |
bool |
Additional protection enabled |
additional_protection_type |
Additional protection type |
|
additional_protection_factor |
float |
Additional protection factor | Δc_dur,add |
allowance_of_deviation_type |
Allowance for deviation type |
|
userdefined_allowance_of_deviation_factor |
float |
User-defined allowance for deviation factor | Δc_dev |
relaxed_quality_control_enabled |
bool |
Reduced inspection level acc. to 4.4.1.3(1) enabled |
concrete_cast_enabled |
bool |
Concrete cast enabled |
concrete_cast |
Concrete cast |
|
comment |
str |
Comment |
is_generated |
bool |
Generated by |
generating_object_info |
str |
Generated by |
id_for_export_import |
str |
|
metadata_for_export_import |
str |
Associated Enums
NoRiskOfCorrosionOrAttack#
Name |
|---|
NO_RISK_OF_CORROSION_OR_ATTACK_VERY_DRY |
CorrosionInducedByCarbonation#
Name |
|---|
CORROSION_INDUCED_BY_CARBONATION_DRY_OR_PERMANENTLY_WET |
CORROSION_INDUCED_BY_CARBONATION_CYCLIC_WET_AND_DRY |
CORROSION_INDUCED_BY_CARBONATION_MODERATE_HUMIDITY |
CORROSION_INDUCED_BY_CARBONATION_WET_RARELY_DRY |
CorrosionInducedByChlorides#
Name |
|---|
CORROSION_INDUCED_BY_CHLORIDES_MODERATE_HUMIDITY |
CORROSION_INDUCED_BY_CHLORIDES_CYCLIC_WET_AND_DRY |
CORROSION_INDUCED_BY_CHLORIDES_WET_RARELY_DRY |
CorrosionInducedByChloridesFromSeaWater#
Name |
|---|
CORROSION_INDUCED_BY_CHLORIDES_FROM_SEA_WATER_EXPOSED_TO_AIRBORNE_SALT |
CORROSION_INDUCED_BY_CHLORIDES_FROM_SEA_WATER_PERMANENTLY_SUBMERGED |
CORROSION_INDUCED_BY_CHLORIDES_FROM_SEA_WATER_TIDAL_SPLASH_AND_SPRAY_ZONES |
FreezeThawAttack#
Name |
|---|
FREEZE_THAW_ATTACK_MODERATE_WATER_SATURATION_NO_DEICING |
FREEZE_THAW_ATTACK_HIGH_WATER_SATURATION_DEICING |
FREEZE_THAW_ATTACK_HIGH_WATER_SATURATION_NO_DEICING |
FREEZE_THAW_ATTACK_MODERATE_WATER_SATURATION_DEICING |
ChemicalAttack#
Name |
|---|
CHEMICAL_ATTACK_SLIGHTLY_AGGRESSIVE |
CHEMICAL_ATTACK_HIGHLY_AGGRESSIVE |
CHEMICAL_ATTACK_MODERATELY_AGGRESSIVE |
ConcreteCorrosionInducedByWear#
Name |
|---|
CONCRETE_CORROSION_INDUCED_BY_WEAR_MODERATE |
CONCRETE_CORROSION_INDUCED_BY_WEAR_HIGH |
CONCRETE_CORROSION_INDUCED_BY_WEAR_VERY_HIGH |
StructuralClassType#
Name |
|---|
STRUCTURAL_CLASS_TYPE_STANDARD |
STRUCTURAL_CLASS_TYPE_DEFINED |
UserdefinedStructuralClass#
Name |
|---|
USERDEFINED_STRUCTURAL_CLASS_UNKNOWN |
USERDEFINED_STRUCTURAL_CLASS_S1 |
USERDEFINED_STRUCTURAL_CLASS_S2 |
USERDEFINED_STRUCTURAL_CLASS_S3 |
USERDEFINED_STRUCTURAL_CLASS_S4 |
USERDEFINED_STRUCTURAL_CLASS_S5 |
USERDEFINED_STRUCTURAL_CLASS_S6 |
DesignWorkingLife#
Name |
|---|
DESIGN_WORKING_LIFE_50_YEARS |
DESIGN_WORKING_LIFE_100_YEARS |
DESIGN_WORKING_LIFE_20_YEARS |
DESIGN_WORKING_LIFE_25_YEARS |
DESIGN_WORKING_LIFE_30_YEARS |
DESIGN_WORKING_LIFE_75_YEARS |
DESIGN_WORKING_LIFE_80_YEARS |
MaximumEquivalentWaterToCementRatio#
Name |
|---|
MAXIMUM_EQUIVALENT_WATER_TO_CEMENT_RATIO_0_350 |
MAXIMUM_EQUIVALENT_WATER_TO_CEMENT_RATIO_0_000 |
MAXIMUM_EQUIVALENT_WATER_TO_CEMENT_RATIO_0_400 |
MAXIMUM_EQUIVALENT_WATER_TO_CEMENT_RATIO_0_450 |
MAXIMUM_EQUIVALENT_WATER_TO_CEMENT_RATIO_0_500 |
MAXIMUM_EQUIVALENT_WATER_TO_CEMENT_RATIO_0_550 |
MAXIMUM_EQUIVALENT_WATER_TO_CEMENT_RATIO_0_600 |
MAXIMUM_EQUIVALENT_WATER_TO_CEMENT_RATIO_0_900 |
IncreaseOfMinimumConcreteCoverType#
Name |
|---|
INCREASE_OF_MINIMUM_CONCRETE_COVER_TYPE_STANDARD |
INCREASE_OF_MINIMUM_CONCRETE_COVER_TYPE_DEFINED |
StainlessSteelType#
Name |
|---|
STAINLESS_STEEL_TYPE_STANDARD |
STAINLESS_STEEL_TYPE_DEFINED |
AdditionalProtectionType#
Name |
|---|
ADDITIONAL_PROTECTION_TYPE_STANDARD |
ADDITIONAL_PROTECTION_TYPE_DEFINED |
AllowanceOfDeviationType#
Name |
|---|
ALLOWANCE_OF_DEVIATION_TYPE_STANDARD |
ALLOWANCE_OF_DEVIATION_TYPE_DEFINED |
ConcreteCast#
Name |
|---|
CONCRETE_CAST_AGAINST_PREPARED_GROUND |
CONCRETE_CAST_DIRECTLY_AGAINST_SOIL |